LANTIME M100 : NTP Time Server with Internal Reference Clock for DIN Rail Installations

LANTIME M100 time servers can be installed to provide accurate time to small and medium sized computer networks. This entry level time server synchronises all NTP and SNTP capable systems utilising a built-in Meinberg radio clock as its primary reference time source. A stable and precise oscillator is capable of bridging interferences or a temporary loss of reception. Its compact form factor offers an ideal solution to network time synchronisation needs in industrial and power generation/distribution networks.

> Request a quote

LANTIME M100 Technical Specifications

Control elements: Serial Terminal Interface (RS232) for initial configuration, Status LEDs
Status info
Four bicolor LEDs showing status of:
– reference time
– time service
– network
– alarm
Network Interface: RJ-45 Network Connection 10/100 MBit
Power supply
Standard:
100-240 VDC / 100-240 VAC,(50/60 Hz)
Option: 19-72 VDC
Power consumption: 20W
Universal Serial Bus (USB) Ports
1x USB Port in front panel:
– install firmware upgrades
– backup and restore configuration files
– copy security keys
– lock/unlock front keys
CPU
AMD Geode™ LX 800 (500 MHz, 128 KB L2 cache, 3.6 W)
Main Memory: onboard 256 MByte
Flashdisk: 1 GB
Operating System of the SBC: Linux with nano kernel (incl. PPSkit)
Network protocols OSI Layer 4 (transport layer): TCP, UDP
Network protocols OSI Layer 7 (application layer):
TELNET, FTP, SSH (incl. SFTP, SCP), HTTP, HTTPS, SYSLOG, SNMP
Internet Protocol (IP): IP v4, IP v6
Network Autoconfiguration Support:
IPv4: Dynamic Host Configuration Protocol – DHCP (RFC 2131)
IPv6: Dynamic Host Configuration Protocol – DHCPv6 (RFC 3315) and Autoconfiguration Networking – AUTOCONF (RFC 2462)
Network Time Protocol (NTP):
NTP v2 (RFC 1119), NTP v3 (RFC 1305), NTP v4 (RFC 5905)
SNTP v3 (RFC 1769), SNTP v4 (RFC 2030)
MD5 Authentication and Autokey Key Management
Time Protocol (TIME): Time Protocol (RFC 868)
Daytime Protocol (DAYTIME): Daytime Protocol (RFC 867)
IEC 61850: Synchronization of IEC 61850 compliant devices by using SNTP
Hypertext Transfer Protocol (HTTP): HTTP/HTTPS (RC 2616)
Secure Shell (SSH): SSH v1.3, SSH v1.5, SSH v2 (OpenSSH)
Telnet: Telnet (RFC 854-RFC 861)
Form Factor: DIN Rail mountable Aluminium Profile chassis (125,5mm x 105mm x 189mm / W x H x D)
Ambient temperature: 0 … 50°C / 32 … 122°F
Humidity: Max. 85%
Scope of supply: Included in delivery is a MEINBERG outdoor antenna incl. mounting kit, pre-assembled antenna cable (except MRS, TCR and RDT models) and product documentation on USB storage.
Technical Support: Meinberg offers free lifetime technical support via telephone or e-mail.
Warranty:Three-Year Warranty
Firmware Updates: Firmware is field-upgradeable, updates can be installed directly at the unit or via a remote network connection.
Software updates are provided free of charge, for the lifetime of your Meinberg product.
RoHS-Status of the product: This product is fully RoHS compliant
WEEE status of the product: This product is handled as a B2B category product. In order to secure a WEEE compliant waste disposal it has to be returned to the manufacturer. Any transportation expenses for returning this product (at its end of life) have to be incurred by the end user, whereas Meinberg will bear the costs for the waste disposal itself.
Additional Information: Additional information about the Meinberg LANTIME family of NTP time servers and other LANTIME models can be found on the LANTIME NTP Time Server Family Page.

 

> Click to view product manuals and additional LANTIME M100 product information on the Meinberg website

APC Technology Group plc

LANTIME M400 : NTP Time Server with Reference Clock for Industrial Applications

The LANTIME M400 time server offers unparalleled flexibility and versatility and provides accurate time to your network in a compact and full-featured DIN rail mount package for industrial applications such as power generation, transmission and distribution (substation automation), process control and industrial automation systems. The M400 includes an LC display and keypad and an extremely broad range of available options.

> Request a quote

LANTIME M400 Technical Specifications

Display: LC-Display, 4 x 16 characters
Control elements: Eight push buttons to set up basic network parameters and to change receiver settings
Status info:
Four bicolor LEDs showing status of:
– reference time
– time service
– network
– alarm
Frequency outputs: 10 MHz via female BNC connector, TTL into 50 Ohm
Accuracy depends on oscillator (standard: TCXO), look at Delete oscillator list
Pulse outputs: Pulse Per Second (PPS), TTL level, pulse width: 200ms
Accuracy of pulse outputs:
Depends on oscillator option:
< ±100ns (TCXO, OCXO LQ)
< ±50ns (OCXO MQ, OCXO HQ, OCXO DHQ)
Interface: Single serial RS232 interface (no serial interface in case of an internal time code receiver).
Data format of interfaces:
Baud rates: 300, 600, 1200, 2400, 4800, 9600, 19200 Baud
Data formats: 7N2, 7E1, 7E2, 7O1, 8E1, 8N1, 8O1
Time strings: Meinberg Standard-Telegram , SAT, Uni Erlangen (NTP), SPA, RACAL, Sysplex, NMEA0183 (RMC, GGA, ZDA), Meinberg GPS, COMPUTIME, ION oder Capture-Telegramm
Physical dimensions: 105 x 189 x 146 mm (W x H x D)
Alarm output: Synchronous state of the module, relay output (changeover contact)
Network Interface: 1 x 10/100 MBit with RJ45 (up to 4 additional LAN interfaces possible)
Power supply
Standard:
100-240 VDC / 100-240 VAC,(50/60 Hz)
Option: 19-72 VDC
Power consumption: 30W
Universal Serial Bus (USB) Ports
1x USB Port:
– install firmware upgrades
– backup and restore configuration files
– copy security keys
– lock/unlock front keys
Supported Time String Formats: Meinberg Standard Timestring, Uni Erlangen Timestring, SYSPLEX Timer, NMEA, Computime, ABB-SPA, SAT, Arbiter
CPU:
AMD Geode™ LX 800 (500 MHz, 128 KB L2 cache, 3.6 W)
Main Memory: onboard 256 MByte
Flashdisk: 1 GB
Operating System of the SBC: Linux with nano kernel (incl. PPSkit)
Network protocols OSI Layer 4 (transport layer): TCP, UDP
Network protocols OSI Layer 7 (application layer):
TELNET, FTP, SSH (incl. SFTP, SCP), HTTP, HTTPS, SYSLOG, SNMP
Internet Protocol (IP): IP v4, IP v6
Network Autoconfiguration Support
IPv4: Dynamic Host Configuration Protocol – DHCP (RFC 2131)
IPv6: Dynamic Host Configuration Protocol – DHCPv6 (RFC 3315) and Autoconfiguration Networking – AUTOCONF (RFC 2462)
Network Time Protocol (NTP)
NTP v2 (RFC 1119), NTP v3 (RFC 1305), NTP v4 (RFC 5905)
SNTP v3 (RFC 1769), SNTP v4 (RFC 2030)
MD5 Authentication and Autokey Key Management
Time Protocol (TIME): Time Protocol (RFC 868)
Daytime Protocol (DAYTIME): Daytime Protocol (RFC 867)
IEC 61850: Synchronization of IEC 61850 compliant devices by using SNTP
Hypertext Transfer Protocol (HTTP): HTTP/HTTPS (RC 2616)
Secure Shell (SSH): SSH v1.3, SSH v1.5, SSH v2 (OpenSSH)
Telnet: Telnet (RFC 854-RFC 861)
Simple Network Management Protocol (SNMP): SNMPv1 (RFC 1157), SNMPv2c (RFC 1901-1908), SNMP v3 (RFC 3411-3418)
Form Factor: Fischer aluminium housing for DIN mounting rail
Ambient temperature: 0 … 50°C / 32 … 122°F
Humidity: Max. 85%
Scope of supply: Included in delivery is a MEINBERG outdoor antenna incl. mounting kit, pre-assembled antenna cable (except MRS, TCR and RDT models) and product documentation on USB storage.
Technical Support: Meinberg offers free lifetime technical support via telephone or e-mail.
Warranty: Three-Year Warranty
Firmware Updates: Firmware is field-upgradeable, updates can be installed directly at the unit or via a remote network connection.
Software updates are provided free of charge, for the lifetime of your Meinberg product.
RoHS-Status of the product: This product is fully RoHS compliant
WEEE status of the product: This product is handled as a B2B category product. In order to secure a WEEE compliant waste disposal it has to be returned to the manufacturer. Any transportation expenses for returning this product (at its end of life) have to be incurred by the end user, whereas Meinberg will bear the costs for the waste disposal itself.
Additional Information: Additional information about the Meinberg LANTIME family of NTP time servers and other LANTIME models can be found on the LANTIME NTP Time Server Family Page.

 

 

> Click to view product manuals and additional LANTIME M400 product information on the Meinberg website

 

All our NTP Time Servers come with a wide range of customisation options.

For technical support and assistance in specifying the optimum time synchronisation solution for your organisation, contact APC Time on: