PTP grandmaster clocks

PTP grandmaster clocks

PTP Grandmaster Clocks

APC Technology Group plc

LANTIME M1000 : Time and Frequency Synchronisation Platform in 1U Rackmount-Enclosure

Versatile and modular solution for Time and Frequency Synchronisation Application in 1U housing.

The 1U chassis has two power supply slots, optional two clock module slots, a CPU slot and four (three in case of a second reference clock or certain oscillator option) slots for additional input and output modules. Adding a second clock module and a second power supply transforms the IMS – M1000 into a fully redundant solution. Both, wide range AC and a 20-72 VDC power supply model can be mixed and matched as required.

> Request a quote

LANTIME M1000 Technical Specifications

Reference Options
The following reference sources can be used to synchronize the system:
GPS – Global Positioning System
GLONASS – Russian GNSS
GALILEO – European GNSS
BeiDou – Chinese GNSS
PZF – German DCF77 longwave radio signal
PTP/IEEE1588 – Precision Time Protocol
NTP – Network Time Protocol
SyncE – Synchronous Ethernet
Timecodes – IRIG/AFNOR timecodes (AM/DCLS)
PPS -Pulse Per Second
10MHz – 10MHz reference frequency
2.048kHz – 2.048kHz reference frequency
E1/T1 – Telecom Synchronization Input with full SSM/BOC support
The priority of all input signals can be freely configured in addition to a bias value and a precision level specification for each source.
Display: LC-Display, 4 x 16 characters
Control elements: Eight push buttons to set up basic network parameters and to change system settings.
Status info:
Four bicolor LEDs showing status of:
– reference time
– time service
– network
– alarm
Two status LEDs for the optional use of an ACM (Active Cooling Module) with two fans – Fan 1 and Fan-2.
Frequency outputs: Accuracy depends on oscillator (standard: OCXO-SQ), see oscillator list
Accuracy of pulse outputs:
Depends on oscillator option:
< ±100ns (TCXO, OCXO LQ)
< ±50ns (OCXO SQ, OCXO MQ, OCXO HQ, OCXO DHQ, Rubidium)
Network Interface
Basic Chassis: 1 x 10/100 MBit with RJ45 connector

Network Expansion – LNE Options:
Up to a maximum of 16 additional 10/100/1000Mbps (GbE Gigabit support) network interfaces with RJ45 connector.
Power supply
100-240 V AC (50/60 Hz) / 100-240 V DC
Redundant Power Supplies and other DC input voltage ranges available upon request
Power consumption: 50W (max. 100W)
Universal Serial Bus (USB) Ports:
1x USB Port in front panel:
– install firmware upgrades
– backup and restore configuration files
– copy security keys
– lock/unlock front keys
CPU
AMD Geode™ LX 800 (500 MHz, 128 KB L2 cache, 3.6 W)
Main Memory: onboard 256 MByte
Flashdisk: 1 GB
Operating System of the SBC: GNU/Linux 4.x
Network protocols OSI Layer 4 (transport layer):
TCP, UDP
Network protocols OSI Layer 7 (application layer): TELNET, FTP, SSH (incl. SFTP, SCP), HTTP, HTTPS, SYSLOG, SNMP
Internet Protocol (IP): IP v4, IP v6
Network Autoconfiguration Support: IPv4: Dynamic Host Configuration Protocol – DHCP (RFC 2131)
IPv6: Dynamic Host Configuration Protocol – DHCPv6 (RFC 3315) and Autoconfiguration Networking – AUTOCONF (RFC 2462)
Network Time Protocol (NTP)
NTP v2 (RFC 1119), NTP v3 (RFC 1305), NTP v4 (RFC 5905)
SNTP v3 (RFC 1769), SNTP v4 (RFC 2030)
MD5 Authentication and Autokey Key Management
Time Protocol (TIME): Time Protocol (RFC 868)
Daytime Protocol (DAYTIME): Daytime Protocol (RFC 867)
IEC 61850: Synchronization of IEC 61850 compliant devices by using SNTP
Hypertext Transfer Protocol (HTTP)HTTP/HTTPS (RC 2616)
Secure Shell (SSH): SSH v1.3, SSH v1.5, SSH v2 (OpenSSH)
Telnet: Telnet (RFC 854-RFC 861)
Simple Network Management Protocol (SNMP): SNMPv1 (RFC 1157), SNMPv2c (RFC 1901-1908), SNMP v3 (RFC 3411-3418)
Form Factor: 19 inch rackmount case, black 1U/84HE
Ambient temperature: 0 … 50°C / 32 … 122°F
Humidity: Max. 85%
Scope of supply: Product documentation and software on USB storage device.
Technical Support: Meinberg offers free lifetime technical support via telephone or e-mail.
Warranty: Three-Year Warranty
Firmware Updates: Firmware is field-upgradeable, updates can be installed directly at the unit or via a remote network connection.
Software updates are provided free of charge, for the lifetime of your Meinberg product.
RoHS-Status of the product: This product is fully RoHS compliant
WEEE status of the product: This product is handled as a B2B category product. In order to secure a WEEE compliant waste disposal it has to be returned to the manufacturer. Any transportation expenses for returning this product (at its end of life) have to be incurred by the end user, whereas Meinberg will bear the costs for the waste disposal itself.
Additional Information: Additional information about the Meinberg LANTIME family of NTP time servers and other LANTIME models can be found on the LANTIME NTP Time Server Family Page.

 

> Click to view product manuals and additional SyncFire 1100 product information on the Meinberg website

APC Technology Group plc

LANTIME M3000 : Versatile and Modular Time and Frequency Synchronisation Platform

The new LANTIME M3000 is a field-upgradeable and extremely flexible system that covers your synchronisation needs – today and in the future.

The M3000 chassis has four power supply slots, two clock module slots, a seamless switchover card slot, a CPU slot and ten slots for additional input and output modules. Adding a second clock module and the required RSC switch module will turn the M3000 into a fully redundant solution. Up to four power supplies can be installed, offering protection against the failure of one or more power sources or power supply failures. Both wide range AC and an 18-72VDC power supply model can be mixed and matched as required.

The possibility to add input and output modules as well as specialized communication cards for NTP and PTP/IEEE1588 network synchronization and remote management ensures that a LANTIME M3000 will fulfil all your synchronization requirements and the scalability and flexibility of the IMS platform concept enables it to cope with the changing demands of your critical applications.

> Request a quote

LANTIME M3000 Technical Specifications

Reference Options
The following reference sources can be used to synchronize the system:
GPS – Global Positioning System
GLONASS – Russian GNSS
GALILEO – European GNSS
BeiDou – Chinese GNSS
PZF – German DCF77 longwave radio signal
PTP/IEEE1588 – Precision Time Protocol
NTP – Network Time Protocol
SyncE – Synchronous Ethernet
Timecodes – IRIG/AFNOR timecodes (AM/DCLS)
PPS -Pulse Per Second
10MHz – 10MHz reference frequency
2.048kHz – 2.048kHz reference frequency
E1/T1 – Telecom Synchronization Input with full SSM/BOC support
The priority of all input signals can be freely configured in addition to a bias value and a precision level specification for each source.
Display: LC-Display, 4 x 16 characters
Control elements: Eight push buttons to set up basic network parameters and to change system settings.
Status info
Four bicolor LEDs showing status of:
– reference time
– time service
– network
– alarm
Two status LEDs for the optional use of an ACM (Active Cooling Module) with two fans – Fan 1 and Fan-2.
Frequency outputs: Accuracy depends on oscillator (standard: OCXO-SQ), see oscillator list
Accuracy of pulse outputs: < ±100ns
Network Interface
Basic Chassis: 1 x 10/100 MBit with RJ45 connector

Network Expansion – LNE Options:
Up to a maximum of 40 additional 10/100/1000Mbps (GbE Gigabit support) network interfaces with RJ45 connector.
Power supply:
100-240 V AC (50/60 Hz) / 100-240 V DC
Redundant Power Supplies and other DC input voltage ranges available upon request
Power consumption: 50W (max. 100W)
Universal Serial Bus (USB) Ports
1x USB Port in front panel:
– install firmware upgrades
– backup and restore configuration files
– copy security keys
– lock/unlock front keys
CPU
AMD Geode™ LX 800 (500 MHz, 128 KB L2 cache, 3.6 W)
Main Memory: onboard 256 MByte
Flashdisk: 1 GB
Operating System of the SBC: GNU/Linux 4.x
Network protocols OSI Layer 4 (transport layer): TCP, UDP
Network protocols OSI Layer 7 (application layer):
TELNET, FTP, SSH (incl. SFTP, SCP), HTTP, HTTPS, SYSLOG, SNMP
Internet Protocol (IP): IP v4, IP v6
Network Autoconfiguration Support
IPv4: Dynamic Host Configuration Protocol – DHCP (RFC 2131)
IPv6: Dynamic Host Configuration Protocol – DHCPv6 (RFC 3315) and Autoconfiguration Networking – AUTOCONF (RFC 2462)
Network Time Protocol (NTP):
NTP v2 (RFC 1119), NTP v3 (RFC 1305), NTP v4 (RFC 5905)
SNTP v3 (RFC 1769), SNTP v4 (RFC 2030)
MD5 Authentication and Autokey Key Management
Time Protocol (TIME): Time Protocol (RFC 868)
Daytime Protocol (DAYTIME): Daytime Protocol (RFC 867)
IEC 61850: Synchronization of IEC 61850 compliant devices by using SNTP
Hypertext Transfer Protocol (HTTP): HTTP/HTTPS (RC 2616)
Secure Shell (SSH): SSH v1.3, SSH v1.5, SSH v2 (OpenSSH)
Telnet: Telnet (RFC 854-RFC 861)
Simple Network Management Protocol (SNMP): SNMPv1 (RFC 1157), SNMPv2c (RFC 1901-1908), SNMP v3 (RFC 3411-3418)
Form Factor:
Modular rackmount 3U chassis for standard 19” racks
483 mm x 132 mm x 270 mm (B x H x T)
Ambient temperature: 0 … 50°C / 32 … 122°F
Humidity: Max. 85%
Scope of supply: Product documentation and software on USB storage device.
Technical Support: Meinberg offers free lifetime technical support via telephone or e-mail.
Warranty: Three-Year Warranty
Firmware Updates
Firmware is field-upgradeable, updates can be installed directly at the unit or via a remote network connection.
Software updates are provided free of charge, for the lifetime of your Meinberg product.
RoHS-Status of the product: This product is fully RoHS compliant
WEEE status of the product: This product is handled as a B2B category product. In order to secure a WEEE compliant waste disposal it has to be returned to the manufacturer. Any transportation expenses for returning this product (at its end of life) have to be incurred by the end user, whereas Meinberg will bear the costs for the waste disposal itself.
Additional Information: Additional information about the Meinberg LANTIME family of NTP time servers and other LANTIME models can be found on the LANTIME NTP Time Server Family Page .

 

> Click to view product manuals and additional LANTIME M3000 product information on the Meinberg website

APC Technology Group plc

LANTIME M4000 : Ultra-Versatile Platform for Telecom Synchronisation Application

The Meinberg LANTIME M4000 has been designed to fulfil the synchronisation requirements of modern 4G/5G/LTE networks. It is capable to act as a Primary Reference Time Clock (PRTC) and, because of its unmatched flexibility, can be deployed in different scenarios. The modularity of the IMS platform (Intelligent Modular Synchronisation system) allows the M4000 to be configured for all areas of a mobile backhaul network: in the core, metro or access network areas.

> Request a quote

LANTIME M4000 Technical Specifications

Reference Options:

The following reference sources can be used to synchronize the system:
GPS – Global Positioning System
GLONASS – Russian GNSS
GALILEO – European GNSS
BeiDou – Chinese GNSS
PZF – German DCF77 longwave radio signal
PTP/IEEE1588 – Precision Time Protocol
NTP – Network Time Protocol
SyncE – Synchronous Ethernet
Timecodes – IRIG/AFNOR timecodes (AM/DCLS)
PPS -Pulse Per Second
10MHz – 10MHz reference frequency
2.048kHz – 2.048kHz reference frequency
E1/T1 – Telecom Synchronization Input with full SSM/BOC support
The priority of all input signals can be freely configured in addition to a bias value and a precision level specification for each source.

Display: LC-Display, 4 x 16 characters
Control elements: Eight push buttons to set up basic network parameters and to change system settings.
Status info:
Four bicolor LEDs showing status of:
– reference time
– time service
– network
– alarm
Frequency outputs: Accuracy depends on oscillator (standard: OCXO-SQ), see oscillator list
Accuracy of pulse outputs: < ±100ns
Network Interface:
Basic Chassis: 1 x 10/100 MBit with RJ45 connector

Network Expansion – LNE Options:
Up to a maximum of 40 additional 10/100/1000Mbps (GbE Gigabit support) network interfaces with RJ45 connector.
Power supply:
100-240 V AC (50/60 Hz) / 100-240 V DC
Redundant Power Supplies and other DC input voltage ranges available upon request
Power consumption: 50W (max. 100W)
Universal Serial Bus (USB) Ports:
1x USB Port in front panel:
– install firmware upgrades
– backup and restore configuration files
– copy security keys
– lock/unlock front keys
CPU:
AMD Geodeâ„¢ LX 800 (500 MHz, 128 KB L2 cache, 3.6 W)
Main Memory: onboard 256 MByte
Flashdisk: 1 GB
Operating System of the SBC: GNU/Linux 4.x
Network protocols OSI Layer 4 (transport layer): TCP, UDP
Network protocols OSI Layer 7 (application layer)
TELNET, FTP, SSH (incl. SFTP, SCP), HTTP, HTTPS, SYSLOG, SNMP
Internet Protocol (IP): IP v4, IP v6
Network Autoconfiguration Support:
IPv4: Dynamic Host Configuration Protocol – DHCP (RFC 2131)
IPv6: Dynamic Host Configuration Protocol – DHCPv6 (RFC 3315) and Autoconfiguration Networking – AUTOCONF (RFC 2462)
Network Time Protocol (NTP):
NTP v2 (RFC 1119), NTP v3 (RFC 1305), NTP v4 (RFC 5905)
SNTP v3 (RFC 1769), SNTP v4 (RFC 2030)
MD5 Authentication and Autokey Key Management
Time Protocol (TIME): Time Protocol (RFC 868)
Daytime Protocol (DAYTIME): Daytime Protocol (RFC 867)
IEC 61850: Synchronization of IEC 61850 compliant devices by using SNTP
Hypertext Transfer Protocol (HTTP): HTTP/HTTPS (RC 2616)
Secure Shell (SSH): SSH v1.3, SSH v1.5, SSH v2 (OpenSSH)
Telnet: Telnet (RFC 854-RFC 861)
Simple Network Management Protocol (SNMP): SNMPv1 (RFC 1157), SNMPv2c (RFC 1901-1908), SNMP v3 (RFC 3411-3418)
Ambient temperature: 0 … 50°C / 32 … 122°F
Humidity: Max. 85%
Scope of supply: Product documentation and software on USB storage device.
Technical Support: Meinberg offers free lifetime technical support via telephone or e-mail.
Warranty: Three-Year Warranty
Firmware Updates:
Firmware is field-upgradeable, updates can be installed directly at the unit or via a remote network connection.
Software updates are provided free of charge, for the lifetime of your Meinberg product.
RoHS-Status of the product: This product is fully RoHS compliant
WEEE status of the product: This product is handled as a B2B category product. In order to secure a WEEE compliant waste disposal it has to be returned to the manufacturer. Any transportation expenses for returning this product (at its end of life) have to be incurred by the end user, whereas Meinberg will bear the costs for the waste disposal itself.

> Click to view product manuals and additional IMS LANTIME M4000 product information on the Meinberg website

APC Technology Group plc

LANTIME M600 : High End NTP Time Server

The Meinberg LANTIME M600 time server is used around the world to provide accurate time to networks of any size. The M600 is the first entry-level grandmaster server capable of supporting IEEE1588 for grandmaster and slave purposes.

When configured as a grandmaster the M600 has several pre-programmed profiles for a variety of different industry requirements including telecom, power and broadcast. A high quality precision OCXO is standard in the M600, to allow this time server to meet the stringent holdover requirements.

> Request a quote

LANTIME M600 Technical Specifications

Type of receiver:
12 channel GPS C/A-code receiver
or
32 channel combined GPS / GLONASS receiver:
frequency band: GPS L1, GLONASS L1
Type of antenna: Remote powered GPS antenna/converter unit, up to 300m distance to antenna with RG58 and up to 700m distance with RG213 cable
Display: Vacuum fluorescent graphic display (VFD), 256 x 64 dots
Control elements: Eight push buttons to set up basic network parameters and to change receiver settings
Status info:
Four bicolor LEDs showing status of:
– reference time
– time service
– network
– alarm
Frequency outputs:
10 MHz via female BNC connector, TTL into 50 Ohm
Synthesizer 1/8 Hz up to 10 MHz via female BNC connector, TTL into 50 Ohm
Accuracy depends on oscillator (standard: OCXO HQ), look at oscillator options
Pulse outputs: Pulse per second (PPS) and pulse per minute (PPM) via female BNC connectors, TTL into 50 Ohm, pulse width: 200msec, active high
Accuracy of pulse outputs: < ±50ns (OCXO HQ, OCXO DHQ)
Interface: Two independent serial RS232-interfaces, menu configurable
Data format of interfaces:
Baud rates: 300, 600, 1200, 2400, 4800, 9600, 19200 Baud
Data formats: 7N2, 7E1, 7E2, 7O1, 8E1, 8N1, 8O1
Time strings: Meinberg Standard-Telegram , SAT, Uni Erlangen (NTP), SPA, RACAL, Sysplex, NMEA0183 (RMC, GGA, ZDA), Meinberg GPS, COMPUTIME, ION oder Capture-Telegramm
Unmodulated time code output: DCLS, TTL into 50 Ohm via female BNC connector, active high
Modulated time code output:
IRIG AM sine wave signal via female BNC connector:
3Vpp (MARK), 1Vpp (SPACE) into 50 Ohm
Generated time codes:
IRIG B002: 100pps, DCLS signal, no carrier, BCD time of year
IRIG B122: 100pps, AM sine wave signal, 1 kHz carrier, BCD time of year
IRIG B003: 100pps, DCLS signal, no carrier, BCD time of year, SBS time of day
IRIG B123: 100pps, AM sine wave signal, 1kHz carrier, BCD time of year, SBS time of day
IRIG B006: 100 pps, DCLS Signal, no carrier, BCD time-of-year, Year
IRIG B126: 100 pps, AM sine wave signal, 1 kHz carrier frequency, BCD time-of-year, Year
IRIG B007: 100 pps, DCLS Signal, no carrier, BCD time-of-year, Year, SBS time-of-day
IRIG B127: 100 pps, AM sine wave signal, 1 kHz carrier frequency, BCD time-of-year, Year, SBS time-of-day
IEEE1344: Code according to IEEE1344-1995, 100pps, AM sine wave signal, 1kHz carrier, BCD time of year, SBS time of day, IEEE1344 expansion for date, time zone, daylight saving and leap second in Control Funktions Segment
C37.118: Like IEEE1344 – with turned sign bit for UTC-Offset
AFNOR: Code according to NFS-87500, 100pps, AM sine wave signal, 1kHz carrier, BCD time of year, complete date, SBS time of day
Alarm output: Synchronous state of the module, relay output (changeover contact)
Network Interface:
1 x 10/100 MBit with RJ45, IEEE 1588
5 x 10/100 MBit with RJ45
Power supply:
Standard: 100-240 V AC (50/60 Hz)
available DC variants: 100-240 V DC, 12 V DC and 19 – 72 V DC
Power consumption: 30W
Universal Serial Bus (USB) Ports:
1x USB Port in front panel:
– install firmware upgrades
– backup and restore configuration files
– copy security keys
– lock/unlock front keys
Supported Time String Formats: Meinberg Standard Timestring, Uni Erlangen Timestring, SYSPLEX Timer, NMEA, Computime, ABB-SPA, SAT, Arbiter
CPU:
AMD Geode™ LX 800 (500 MHz, 128 KB L2 cache, 3.6 W)
Main Memory: onboard 256 MByte
Flashdisk: 1 GB
Operating System of the SBC: Linux with nano kernel (incl. PPSkit)
Network protocols OSI Layer 4 (transport layer): TCP, UDP
Network protocols OSI Layer 7 (application layer)
TELNET, FTP, SSH (incl. SFTP, SCP), HTTP, HTTPS, SYSLOG, SNMP
Internet Protocol (IP): IP v4, IP v6
Network Autoconfiguration Support:
IPv4: Dynamic Host Configuration Protocol – DHCP (RFC 2131)
IPv6: Dynamic Host Configuration Protocol – DHCPv6 (RFC 3315) and Autoconfiguration Networking – AUTOCONF (RFC 2462)
Network Time Protocol (NTP):
NTP v2 (RFC 1119), NTP v3 (RFC 1305), NTP v4 (RFC 5905)
SNTP v3 (RFC 1769), SNTP v4 (RFC 2030)
MD5 Authentication and Autokey Key Management
Precision Time Protocol (IEEE 1588):
PTP/ IEEE 1588-2008 including
Network Protocols:
– UDP/IPv4 (Layer 3) (Multicast/Unicast)
– IEEE 802.3 (Layer 2) (Multicast)
Delay Mechanisms:
– End-to-End (Multicast/Unicast)
– Peer-to-Peer (Multicast)
PTP Management Messages for monitoring and configuration
Time Protocol (TIME): Time Protocol (RFC 868)
Daytime Protocol (DAYTIME): Daytime Protocol (RFC 867)
IEC 61850: Synchronization of IEC 61850 compliant devices by using SNTP
Hypertext Transfer Protocol (HTTP): HTTP/HTTPS (RC 2616)
Secure Shell (SSH): SSH v1.3, SSH v1.5, SSH v2 (OpenSSH)
Telnet: Telnet (RFC 854-RFC 861)
Simple Network Management Protocol (SNMP): SNMPv1 (RFC 1157), SNMPv2c (RFC 1901-1908), SNMP v3 (RFC 3411-3418)
Form Factor
Standard – 1U: 442 mm wide x 45 mm high x 288 mm deep
XL housing – 2U: 442 mm wide x 87 mm high x 288 mm deep
(498 mm wide with mounting bracket)
Ambient temperature: 0 … 50°C / 32 … 122°F
Humidity: Max. 85%
Scope of supply: Included in delivery is our GPS antenna incl. converter unit, 20m GPS antenna cable (RG58) and product documentation.
Technical Support: Meinberg offers free lifetime technical support via telephone or e-mail.
Warranty: Three-Year Warranty
Firmware Updates: Firmware is field-upgradeable, updates can be installed directly at the unit or via a remote network connection.
Software updates are provided free of charge, for the lifetime of your Meinberg product.
RoHS-Status of the product: This product is fully RoHS compliant
WEEE status of the product: This product is handled as a B2B category product. In order to secure a WEEE compliant waste disposal it has to be returned to the manufacturer. Any transportation expenses for returning this product (at its end of life) have to be incurred by the end user, whereas Meinberg will bear the costs for the waste disposal itself.
Options and Accessories: Optional add-ons and accessories: Product Options
Additional Information: Additional information about the Meinberg LANTIME family of NTP time servers and other LANTIME models can be found on the LANTIME NTP Time Server Family Page.

 

> Click to view product manuals and additional LANTIME M600 product information on the Meinberg website

APC Technology Group plc

LANTIME M900 : NTP Timeserver Platform for Customized Time and Frequency Synchronization Systems

The Meinberg LANTIME M900 Timeserver can be used all around the world to synchronise even the largest networks in computer centres, industrial network infrastructures and telecom environments. The M900 is Meinberg’s system platform for customised solutions and offers a wide range of possible configurations, including a wealth of choices for time and frequency inputs and outputs as well as redundancy enhancements for fail-safe synchronisation needs.

> Request a quote

LANTIME M900/PTP Techinical Specifications

Display: LC-Display, 4 x 16 characters
Control elements: Eight push buttons to set up basic network parameters and to change receiver settings
Status info:
Four bicolor LEDs showing status of:
– reference time
– time service
– network
– alarm
Frequency outputs:
10 MHz via female BNC connector, TTL into 50 Ohm
Accuracy depends on oscillator (standard: OCXO-HQ), look at oscillator options
Pulse outputs: Pulse Per Second (PPS) via BNC connector (TTL level), pulse width 200ms
Accuracy of pulse outputs
< ±100ns (OCXO HQ, OCXO DHQ, Rubidium)
Interface: Two independent serial RS232-interfaces, menu configurable
Data format of interfaces:
Baud rates: 300, 600, 1200, 2400, 4800, 9600, 19200 Baud
Data formats: 7N2, 7E1, 7E2, 7O1, 8E1, 8N1, 8O1
Time strings: Meinberg Standard-Telegram , SAT, Uni Erlangen (NTP), SPA, RACAL, Sysplex, NMEA0183 (RMC, GGA, ZDA), Meinberg GPS, COMPUTIME, ION oder Capture-Telegramm
Alarm output: Synchronous state of the module, relay output (changeover contact)
Network Interface: 1 x 10/100 MBit with RJ45 (up to 8 additional LAN interfaces possible)
Power supply:
100-240 V AC (50/60 Hz) / 100-240 V DC
Redundant Power Supplies and other DC input voltage ranges available upon request
Power consumption:
Max. 25W with single power supply.
Max. 50W with redundant power solution.
Universal Serial Bus (USB) Ports:
1x USB Port in front panel:
– install firmware upgrades
– backup and restore configuration files
– copy security keys
– lock/unlock front keys
CPU:
AMD Geode™ LX 800 (500 MHz, 128 KB L2 cache, 3.6 W)
Main Memory: onboard 256 MByte
Flashdisk: 1 GB
Operating System of the SBC: Linux with nano kernel (incl. PPSkit)
Network protocols OSI Layer 4 (transport layer): TCP, UDP
Network protocols OSI Layer 7 (application layer): TELNET, FTP, SSH (incl. SFTP, SCP), HTTP, HTTPS, SYSLOG, SNMP
Internet Protocol (IP): IP v4, IP v6
Network Autoconfiguration Support
IPv4: Dynamic Host Configuration Protocol – DHCP (RFC 2131)
IPv6: Dynamic Host Configuration Protocol – DHCPv6 (RFC 3315) and Autoconfiguration Networking – AUTOCONF (RFC 2462)
Network Time Protocol (NTP)
NTP v2 (RFC 1119), NTP v3 (RFC 1305), NTP v4 (RFC 5905)
SNTP v3 (RFC 1769), SNTP v4 (RFC 2030)
MD5 Authentication and Autokey Key Management
Time Protocol (TIME): Time Protocol (RFC 868)
Daytime Protocol (DAYTIME): Daytime Protocol (RFC 867)
IEC 6185: Synchronization of IEC 61850 compliant devices by using SNTP
Hypertext Transfer Protocol (HTTP): HTTP/HTTPS (RC 2616)
Secure Shell (SSH): SSH v1.3, SSH v1.5, SSH v2 (OpenSSH)
Telnet: Telnet (RFC 854-RFC 861)
Simple Network Management Protocol (SNMP): SNMPv1 (RFC 1157), SNMPv2c (RFC 1901-1908), SNMP v3 (RFC 3411-3418)
Form Factor: Rackmount 3U chassis for standard 19” racks
Ambient temperature: 0 … 50°C / 32 … 122°F
Humidity: Max. 85%
Scope of supply: Included in delivery is a MEINBERG outdoor antenna incl. mounting kit, pre-assembled antenna cable (except MRS, TCR and RDT models) and product documentation on USB storage.
Technical Support: Meinberg offers free lifetime technical support via telephone or e-mail.
Warranty: Three-Year Warranty
Firmware Updates: Firmware is field-upgradeable, updates can be installed directly at the unit or via a remote network connection.
Software updates are provided free of charge, for the lifetime of your Meinberg product.
RoHS-Status of the product: This product is fully RoHS compliant
WEEE status of the product: This product is handled as a B2B category product. In order to secure a WEEE compliant waste disposal it has to be returned to the manufacturer. Any transportation expenses for returning this product (at its end of life) have to be incurred by the end user, whereas Meinberg will bear the costs for the waste disposal itself.
Additional Information: Additional information about the Meinberg LANTIME family of NTP time servers and other LANTIME models can be found on the LANTIME NTP Time Server Family Page .

 

> Click to view product manuals and additional SyncFire 1100 product information on the Meinberg website

All our PTP Time Servers come with a wide range of customisation options.

For technical support and assistance in specifying the optimum time synchronisation solution for your organisation, contact APC Time on: