PTP slave devices

PTP slave devices

PTP Slave Devices

APC Technology Group plc

PTP270PEX: IEEE1588-2008 slot card for computers (PCI Express)

The PTP270PEX provides sub-microsecond accuracy for computers. The card has been designed to add ultra precise time stamping capabilities to your data acquisition and measurement applications. The PCI Express card can be installed in any single lane PCIe slot and offers an impressive selection of time, pulse and frequency outputs.

> Request a quote

PTP270PEX Technical Specifications

Accuracy: +-20 ns to grandmaster clock
Status info: 4 Status LEDs:
-System Status
-Outputs active
-PTP packet sent
-PTP packet received
Frequency outputs: Frequency output 10 MHz, TTL level
Pulse outputs: Pulse Per Second (PPS), TTL level, pulse width: 200ms
Accuracy of pulse outputs: +/- 100 ns (relative to the used IEEE 1588 Grandmaster Clock, after initial synchronization phase)
Interface: Single serial RS232 interface
Unmodulated time code output: DCLS, TTL into 50 ohm (active high or active low)
Generated time codes
B002: 100pps, DCLS signal, no carrier, BCD time of year
B003: 100pps, DCLS signal, no carrier, BCD time of year, SBS time of day
IEEE1344: Code according to IEEE1344-1995, 100pps, BCD time of year, SBS time of day, IEEE1344 expansion for date, time zone, daylight saving and leap second in Control Functions segment (CF)
AFNOR: Code according to NFS-87500, 100pps, BCD time of year, complete date, SBS time of day
Time-Trigger inputs:
Resolution: 20 nsec, triggered by falling TTL slope
Time of trigger event readable via PCI Express interface
Computer interface: Single lane (x1) PCI Express (PCIe) Interface
PCI Express r1.0a compatible
Network Interface: 1 x 10/100 MBit with RJ45, IEEE 1588
Power supply:
+3.3V, @ 600mA
+12V, @ 300mA
Board type: Standard height board (101 x 150 mm)
Precision Time Protocol (IEEE 1588):
PTP/ IEEE 1588-2008 Multicast including
Network Protocols:
– UDP/IPv4 (Layer 3)
– IEEE 802.3 (Layer 2)
Delay Mechanisms:
– End-to-End
– Peer-to-Peer
PTP Management Messages for monitoring and configuration
Ambient temperature: 0 … 50°C / 32 … 122°F
Humidity: Max. 85%
Warranty: Three-Year Warranty
Options: Oscillator upgrade:
OCXO-LQ, -MQ or -HQ (instead of TCXO) for extended Holdover capabilities
(see oscillator table for further details)
RoHS-Status of the product: This product is fully RoHS compliant
WEEE status of the product: This product is handled as a B2B category product. In order to secure a WEEE compliant waste disposal it has to be returned to the manufacturer. Any transportation expenses for returning this product (at its end of life) have to be incurred by the end user, whereas Meinberg will bear the costs for the waste disposal itself.

 

> Click to view product manuals and additional PTP270PEX  product information on the Meinberg website

APC Technology Group plc

SyncBox/PTPv2: PTP/IEEE 1588 Slave Clock

The Meinberg SyncBox/PTPv2 simplifies a migration towards PTP/IEEE 1588-2008 by providing a wide range of legacy time synchronization outputs. It is synchronized by a PTP Grandmaster and can be used as a time source for equipment that requires IRIG, PPS, 10MHz or E1 telecom carrier signals.

> Request a quote

SyncBox/PTPv2 Technical Specifications

Control elements: Serial Terminal Interface (RS232) for initial configuration, Status LEDs
Status info:
6 Status LEDs:
System State (Ready)
Outputs enabled
PTP packet sent
PTP packet received
Link 100Mbit/s
Link 10MBit/s
Frequency outputs: 10 MHz via BNC-Connector TTL 50 Ohm Accuracy is depending on oscillator (standard: OCXO HQ), see oscillator list
Pulse outputs: Pulse Per Second (PPS) via BNC connector (TTL level), pulse width 200ms
Accuracy of pulse outputs: +/- 100 ns (relative to the used IEEE 1588 Grandmaster Clock, after initial synchronization phase)
Interface: Single serial RS232 interface
Optional Output Signals:
Additional Telecom Signals (LIU):
2,048 kHz (E1-mode)
G.703, 75 ohm, unbalanced,
G.703, 120 ohm, balanced
2.048 Mbps (E1-mode)
75 ohm , unbalanced
120 ohm , balanced
Unmodulated time code output: DCLS, TTL into 50 Ohm via female BNC connector, active high
Modulated time code output:
IRIG AM sine wave signal via female BNC connector:
3Vpp (MARK), 1Vpp (SPACE) into 50 Ohm
Generated time codes
IRIG B002: 100pps, DCLS signal, no carrier, BCD time of year
IRIG B122: 100pps, AM sine wave signal, 1 kHz carrier, BCD time of year
IRIG B003: 100pps, DCLS signal, no carrier, BCD time of year, SBS time of day
IRIG B123: 100pps, AM sine wave signal, 1kHz carrier, BCD time of year, SBS time of day
IEEE1344: Code according to IEEE1344-1995, 100pps, AM sine wave signal, 1kHz carrier, BCD time of year, SBS time of day, IEEE1344 expansion for date, time zone, daylight saving and leap second in Control Funktions Segment
AFNOR: Code according to NFS-87500, 100pps, AM sine wave signal, 1kHz carrier, BCD time of year, complete date, SBS time of day
Network Interface: 1 x 10/100 MBit with RJ45, IEEE 1588 (PTPv2)
Power supply:
Standard: 100-240 VDC / 100-240 VAC
(also available in different DC variants)
Power consumption: 15W
CPU: ARM compatible 500Mhz CPU, 256 MB RAM
Operating System of the SBC: Linux with nano kernel (incl. PPSkit)
Network protocols OSI Layer 4 (transport layer): TCP, UDP
Network protocols OSI Layer 7 (application layer): TELNET, SSH, HTTP, HTTPS
Internet Protocol (IP): IP v4
Network Autoconfiguration Support: Dynamic Host Configuration Protocol – DHCP (RFC 2131)
Precision Time Protocol (IEEE 1588)
PTP/ IEEE 1588-2008 including
Network Protocols:
– UDP/IPv4 (Layer 3) (Multicast/Unicast)
– IEEE 802.3 (Layer 2) (Multicast)
Delay Mechanisms:
– End-to-End (Multicast/Unicast)
– Peer-to-Peer (Multicast)
PTP Management Messages for monitoring and configuration
Hypertext Transfer Protocol (HTTP): HTTP/HTTPS (RC 2616)
Secure Shell (SSH): SSH v1.3, SSH v1.5, SSH v2 (OpenSSH)
Telnet: Telnet (RFC 854-RFC 861)
Form Factor: Compact slimline chassis, 1U/63HP (335mm wide x 43mm high x 250mm deep)
Ambient temperature: 0 … 50°C / 32 … 122°F
Humidity: Max. 85%
Scope of supply: SyncBox, power cable, USB Flash Drive with manual and Meinberg software
Technical Support: Meinberg offers free lifetime technical support via telephone or e-mail.
Warranty: Three-Year Warranty
Firmware Updates: Firmware is field-upgradeable, updates can be installed directly at the unit or via a remote network connection.
Software updates are provided free of charge, for the lifetime of your Meinberg product.
RoHS-Status of the product: This product is fully RoHS compliant
WEEE status of the product: This product is handled as a B2B category product. In order to secure a WEEE compliant waste disposal it has to be returned to the manufacturer. Any transportation expenses for returning this product (at its end of life) have to be incurred by the end user, whereas Meinberg will bear the costs for the waste disposal itself.

 

> Click to view product manuals and additional SyncBox/PTPv2   product information on the Meinberg website

APC Technology Group plc

LANTIME M600/PTP: PTPv2 / IEEE 1588-2008 Grandmaster Clock and NTP Time Server with integrated GPS or GPS/GLONASS radio clock

The Meinberg LANTIME M600 time server is used around the world to provide accurate time to networks of any size. The M600 is the first entry-level grandmaster server capable of supporting IEEE1588 for grandmaster and slave purposes.

When configured as a slave the M600 is able to be configured to synchronise to either unicast or multicast grandmaster sources and is also able to redistribute PTP v2 if a second port is installed in the system.

> Request a quote

LANTIME M600/PTP Technical Specifications

Type of receiver:
12 channel GPS C/A-code receiver
or
32 channel combined GPS / GLONASS receiver:
frequency band: GPS L1, GLONASS L1
Type of antenna:
Remote powered GPS antenna/converter unit, up to 300m distance to antenna with RG58 and up to 700m distance with RG213 cable
Display: Vacuum fluorescent graphic display (VFD), 256 x 64 dots
Control elements: Eight push buttons to set up basic network parameters and to change receiver settings
Status info:
Four bicolor LEDs showing status of:
– reference time
– time service
– network
– alarm
Frequency outputs:
10 MHz via female BNC connector, TTL into 50 Ohm
Synthesizer 1/8 Hz up to 10 MHz via female BNC connector, TTL into 50 Ohm
Accuracy depends on oscillator (standard: OCXO HQ), look at oscillator options
Pulse outputs: Pulse per second (PPS) and pulse per minute (PPM) via female BNC connectors, TTL into 50 Ohm, pulse width: 200msec, active high
Accuracy of pulse outputs: < ±50ns (OCXO HQ, OCXO DHQ)
Interface: Two independent serial RS232-interfaces, menu configurable
Data format of interfaces:
Baud rates: 300, 600, 1200, 2400, 4800, 9600, 19200 Baud
Data formats: 7N2, 7E1, 7E2, 7O1, 8E1, 8N1, 8O1
Time strings: Meinberg Standard-Telegram , SAT, Uni Erlangen (NTP), SPA, RACAL, Sysplex, NMEA0183 (RMC, GGA, ZDA), Meinberg GPS, COMPUTIME, ION oder Capture-Telegramm
Unmodulated time code output: DCLS, TTL into 50 Ohm via female BNC connector, active high
Modulated time code output:
IRIG AM sine wave signal via female BNC connector:
3Vpp (MARK), 1Vpp (SPACE) into 50 Ohm
Generated time codes
IRIG B002: 100pps, DCLS signal, no carrier, BCD time of year
IRIG B122: 100pps, AM sine wave signal, 1 kHz carrier, BCD time of year
IRIG B003: 100pps, DCLS signal, no carrier, BCD time of year, SBS time of day
IRIG B123: 100pps, AM sine wave signal, 1kHz carrier, BCD time of year, SBS time of day
IRIG B006: 100 pps, DCLS Signal, no carrier, BCD time-of-year, Year
IRIG B126: 100 pps, AM sine wave signal, 1 kHz carrier frequency, BCD time-of-year, Year
IRIG B007: 100 pps, DCLS Signal, no carrier, BCD time-of-year, Year, SBS time-of-day
IRIG B127: 100 pps, AM sine wave signal, 1 kHz carrier frequency, BCD time-of-year, Year, SBS time-of-day
IEEE1344: Code according to IEEE1344-1995, 100pps, AM sine wave signal, 1kHz carrier, BCD time of year, SBS time of day, IEEE1344 expansion for date, time zone, daylight saving and leap second in Control Funktions Segment
C37.118: Like IEEE1344 – with turned sign bit for UTC-Offset
AFNOR: Code according to NFS-87500, 100pps, AM sine wave signal, 1kHz carrier, BCD time of year, complete date, SBS time of day
Alarm output: Synchronous state of the module, relay output (changeover contact)
Network Interface:
1 x 10/100 MBit with RJ45, IEEE 1588
5 x 10/100 MBit with RJ45
Power supply:
Standard: 100-240 V AC (50/60 Hz)
available DC variants: 100-240 V DC, 12 V DC and 19 – 72 V DC
Power consumption: 30W
Universal Serial Bus (USB) Ports: 
1x USB Port in front panel:
– install firmware upgrades
– backup and restore configuration files
– copy security keys
– lock/unlock front keys
Supported Time String Formats: Meinberg Standard Timestring, Uni Erlangen Timestring, SYSPLEX Timer, NMEA, Computime, ABB-SPA, SAT, Arbiter
CPU:
AMD Geode™ LX 800 (500 MHz, 128 KB L2 cache, 3.6 W)
Main Memory: onboard 256 MByte
Flashdisk: 1 GB
Operating System of the SBC: Linux with nano kernel (incl. PPSkit)
Network protocols OSI Layer 4 (transport layer): TCP, UDP
Network protocols OSI Layer 7 (application layer): TELNET, FTP, SSH (incl. SFTP, SCP), HTTP, HTTPS, SYSLOG, SNMP
Internet Protocol (IP): IP v4, IP v6
Network Autoconfiguration Support:
IPv4: Dynamic Host Configuration Protocol – DHCP (RFC 2131)
IPv6: Dynamic Host Configuration Protocol – DHCPv6 (RFC 3315) and Autoconfiguration Networking – AUTOCONF (RFC 2462)
Network Time Protocol (NTP):
NTP v2 (RFC 1119), NTP v3 (RFC 1305), NTP v4 (RFC 5905)
SNTP v3 (RFC 1769), SNTP v4 (RFC 2030)
MD5 Authentication and Autokey Key Management
Precision Time Protocol (IEEE 1588):
PTP/ IEEE 1588-2008 including
Network Protocols:
– UDP/IPv4 (Layer 3) (Multicast/Unicast)
– IEEE 802.3 (Layer 2) (Multicast)
Delay Mechanisms:
– End-to-End (Multicast/Unicast)
– Peer-to-Peer (Multicast)
PTP Management Messages for monitoring and configuration
Time Protocol (TIME): Time Protocol (RFC 868)
Daytime Protocol (DAYTIME): Daytime Protocol (RFC 867)
IEC 61850: Synchronization of IEC 61850 compliant devices by using SNTP
Hypertext Transfer Protocol (HTTP): HTTP/HTTPS (RC 2616)
Secure Shell (SSH): SSH v1.3, SSH v1.5, SSH v2 (OpenSSH)
Telnet: Telnet (RFC 854-RFC 861)
Simple Network Management Protocol (SNMP): SNMPv1 (RFC 1157), SNMPv2c (RFC 1901-1908), SNMP v3 (RFC 3411-3418)
Form Factor:
Standard – 1U: 442 mm wide x 45 mm high x 288 mm deep
XL housing – 2U: 442 mm wide x 87 mm high x 288 mm deep
(498 mm wide with mounting bracket)
Ambient temperature
0 … 50°C / 32 … 122°F
Humidity: Max. 85%
Scope of supply: Included in delivery is our GPS antenna incl. converter unit, 20m GPS antenna cable (RG58) and product documentation.
Technical Support: Meinberg offers free lifetime technical support via telephone or e-mail.
Warranty: Three-Year Warranty
Firmware Updates: Firmware is field-upgradeable, updates can be installed directly at the unit or via a remote network connection.
Software updates are provided free of charge, for the lifetime of your Meinberg product.
RoHS-Status of the product: This product is fully RoHS compliant
WEEE status of the product: This product is handled as a B2B category product. In order to secure a WEEE compliant waste disposal it has to be returned to the manufacturer. Any transportation expenses for returning this product (at its end of life) have to be incurred by the end user, whereas Meinberg will bear the costs for the waste disposal itself.
Options and Accessories: Optional add-ons and accessories: Product Options
Additional Information: Additional information about the Meinberg LANTIME family of NTP time servers and other LANTIME models can be found on the LANTIME NTP Time Server Family Page .

 

> Click to view product manuals and additional LANTIME M600/PTP   product information on the Meinberg website

All our time servers come with a wide range of customisation option.

For technical support and assistance in specifying the optimum time synchronisation solution for your organisation, contact APC Time on: