1119205

1119205

LAPP Cable

VDE-registered oil-resistant PVC control cable for a wide range of applications

ÖLFLEX® CLASSIC 110 - PVC control cable, VDE registered, oil resistant and flexible for various applications, 300/500V, also for YSLY or YY
Contact us for lead time

Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.

1119205 Specifications

  • Flame-retardant according IEC 60332-1-2
  • Good chemical resistance, see catalogue appendix T1
  • Oil-resistant according to DIN EN 50290-2-22 (TM54)
More Information
Attribute Value
Product Brand Name ÖLFLEX® CLASSIC 110
Approvals VDE reg. no. 7030 for the following sizes:up to 2.5 mm²: 2 - 65 coresfrom 4 mm²: 2 - 7 coresfrom 25 mm²: 2 - 5 cores
Approvals
  • VDE reg. no. 7030 for the following sizes:up to 2.5 mm²: 2 - 65 coresfrom 4 mm²: 2 - 7 coresfrom 25 mm²: 2 - 5 cores
Temperature Range Occasional flexing: -15°C to +70°C | In power chains: -5°C to +70°C | Fixed installation: -40°C to +80°C
Extended Description Benefits
  • Wide choice of standardized lengths and individual cuts
  • Very broad range, items with up to 100 conductors
Applications
  • For fixed installation as well as occasional flexing at free, non-continuously recurring movement without tensile load
  • Dry or damp rooms that are subject to medium mechanical loads
  • Suitable for torsional applications which are typical for the loop in wind turbine generators (WTG)
  • In power chains for a travelling distance up to 5 m and 0,2 ... 1 million bending cycles, for following dimensions: 0,5 to 2.5mm² and 2 to 7 conductors
Features
  • Flame-retardant according IEC 60332-1-2
  • Good chemical resistance, see catalogue appendix T1
  • Oil-resistant according to DIN EN 50290-2-22 (TM54)
Product make up
  • Fine-wire strand made of bare copper wires
  • PVC insulation LAPP P8/1
  • Cores twisted in layers
  • PVC outer sheath, grey (similar RAL 7001)
Benefits Wide choice of standardized lengths and individual cuts | Very broad range, items with up to 100 conductors
Features Flame-retardant according IEC 60332-1-2 | Good chemical resistance, see catalogue appendix T1 | Oil-resistant according to DIN EN 50290-2-22 (TM54)
Manufacturer Lapp
Chemical resistant Yes
Power Chain Yes
Number of conductors 5
mm2 per conductor 1.0
Protective Conductor Yes
Outer Diameter (mm) 7.1
Copper index kg per km 48.0000
Core Identification Code Black with white numbers acc. to VDE 0293-334
Nominal Voltage U0/U: 300/500 V
Test Voltage
  • 4000 V
Benefits
  • Wide choice of standardized lengths and individual cuts
  • Very broad range, items with up to 100 conductors
Product Make Up
  • Fine-wire strand made of bare copper wires
  • PVC insulation LAPP P8/1
  • Cores twisted in layers
  • PVC outer sheath, grey (similar RAL 7001)
Product Make Up Fine-wire strand made of bare copper wires | PVC insulation LAPP P8/1 | Cores twisted in layers | PVC outer sheath, grey (similar RAL 7001)
Test Voltage 4000
Core Identification Code HTML
  • Black with white numbers acc. to VDE 0293-334
Conductor Stranding Fine wire according to DIN EN 60228 (VDE 0295), class 5 / IEC 60228 class 5
Conductor Stranding HTML
  • Fine wire according to DIN EN 60228 (VDE 0295), class 5 / IEC 60228 class 5
Minimum Bending Radius Occasional flexing: 10 x outer diameter | In power chains: 15 x outer diameter | Fixed installation: 4 x outer diameter
Minimum Bending Radius
  • Occasional flexing: 10 x outer diameter
  • In power chains: 15 x outer diameter
  • Fixed installation: 4 x outer diameter
Nominal Voltage HTML
  • U0/U: 300/500 V
Temperature Range
  • Occasional flexing: -15°C to +70°C
  • In power chains: -5°C to +70°C
  • Fixed installation: -40°C to +80°C
Technical Data Core identification code
  • Black with white numbers acc. to VDE 0293-334
Conductor stranding
  • Fine wire according to DIN EN 60228 (VDE 0295), class 5 / IEC 60228 class 5
Minimum bending radius
  • Occasional flexing: 10 x outer diameter
  • In power chains: 15 x outer diameter
  • Fixed installation: 4 x outer diameter
Nominal voltage
  • U0/U: 300/500 V
Test voltage
  • 4000 V
Temperature range
  • Occasional flexing: -15°C to +70°C
  • In power chains: -5°C to +70°C
  • Fixed installation: -40°C to +80°C
Applications For fixed installation as well as occasional flexing at free, non-continuously recurring movement without tensile load | Dry or damp rooms that are subject to medium mechanical loads | Suitable for torsional applications which are typical for the loop in wind turbine generators (WTG) | In power chains for a travelling distance up to 5 m and 0,2 ... 1 million bending cycles, for following dimensions: 0,5 to 2.5mm² and 2 to 7 conductors
Applications
  • For fixed installation as well as occasional flexing at free, non-continuously recurring movement without tensile load
  • Dry or damp rooms that are subject to medium mechanical loads
  • Suitable for torsional applications which are typical for the loop in wind turbine generators (WTG)
  • In power chains for a travelling distance up to 5 m and 0,2 ... 1 million bending cycles, for following dimensions: 0,5 to 2.5mm² and 2 to 7 conductors
Weight kg per km 94.0000
More Information