1123438
1123438
LAPP Cable
0.6/1kVAC, Halogen-free, Flexible, IEC 60332-3, IEC 61034-2, UV/ ozone resistance, UL AWM 1000V
ÖLFLEX® CLASSIC 130 H BK 0,6/1 kV Power and Control Cable UL AWM Style 21156, Conductor class 5, Halogen-free/ Highly Flame Retardant, Public buildings, Outdoor
Contact us for lead time
Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.
1123438 Specifications
- Flame-retardant according to IEC 60332-1-2 (flame spread on a single cable)
- No flame-propagation according to IEC 60332-3-24 respectively IEC 60332-3-25 (Flame spread on vertical cable or wire bundle)
- Halogen-free according to IEC 60754-1 (amount of halogen acid gas - Corrosiveness of combustion gases according to IEC 60754-2 (degree of acidity)
- Low smoke density according to IEC 61034-2
- UV and weather-resistant according to ISO 4892-2
- Ozone-resistant according to EN 50396
Attribute | Value |
---|---|
Product Brand Name | ÖLFLEX® CLASSIC 130 H BK 0,6/1 kV |
Approvals | Based on EN 50525-3-11 | UL AWM approval: refer to data sheet |
Approvals |
|
Temperature Range | Occasional flexing: -25°C to +70°C | Fixed installation: -40°C to +80°C | UL: -25°C to +75°C |
Extended Description |
Benefits
|
Benefits | Easy installation due to flexible design |
Features | Flame-retardant according to IEC 60332-1-2 (flame spread on a single cable) | No flame-propagation according to IEC 60332-3-24 respectively IEC 60332-3-25 (Flame spread on vertical cable or wire bundle) | Halogen-free according to IEC 60754-1 (amount of halogen acid gas - Corrosiveness of combustion gases according to IEC 60754-2 (degree of acidity) | Low smoke density according to IEC 61034-2 | UV and weather-resistant according to ISO 4892-2 | Ozone-resistant according to EN 50396 |
Manufacturer | Lapp |
Outdoor Use | Yes |
Halogen free | Yes |
Cold resistant | Yes |
UV Resistant | Yes |
Flame Retardant | Yes |
Number of conductors | 4 |
mm2 per conductor | 6 |
Protective Conductor | Yes |
Outer Diameter (mm) | 15.1 |
Copper index kg per km | 230.4 |
Core Identification Code | Up to 5 cores: colour-coded according to VDE 0293-308, refer to Appendix T9 | From 6 cores: black with white numbers |
Nominal Voltage | U0/U: 600/1000 V | UL: 1000 V |
Test Voltage |
|
Benefits |
|
Product Make Up |
|
Product Make Up | Fine-wire strand made of bare copper wires | Core insulation: Halogen-free | Outer sheath made of special halogen-free coumpound, black |
Test Voltage | 4000 |
Core Identification Code HTML |
|
Conductor Stranding | Fine wire according to VDE 0295, class 5/IEC 60228 class 5 |
Conductor Stranding HTML |
|
Minimum Bending Radius | Occasional flexing: 15 x outer diameter | Fixed installation: 4 x outer diameter |
Minimum Bending Radius |
|
Nominal Voltage HTML |
|
Temperature Range |
|
Technical Data |
Core identification code
|
Applications | Plant engineering, Industrial machinery, Heating and air-conditioning systems | Particularly where human and animal life as well as valuable property are exposed to high risk of fire hazards | For outdoor applications | According to NFPA 79, subchapter 12.9.2: Use for industrial machinery operated in the USA on the basis of UL AWM (recognized) certification | Each dimension with nominal/ minimum average wall thickness of the outer sheath of at least 1.8 mm: For applications where a strengthened outer sheath may turn out to be advantageous |
Applications |
|
Weight kg per km | 463.0000 |
Attribute | Value |
---|---|
Data Sheet | Click here to view |