Bird

500mW - 500W Avg, 1000W Peak Wideband RF Power Sensor

500mW - 500W Avg, 1000W Peak Wideband RF Power Sensor The 5017D RF Power Sensor never requires field calibration, only requires calibration once per year and is traceable to National Institute of Standards and Technology (NIST). The WPS measures True Average Power, Peak Power, and Duty Cycle directly with exceptional accuracy and uses these precise measurements to calculate a wide range of other important factors, such as VSWR, Return Loss, Reflection Coefficient, Crest Factor, Average Burst Power, and CCDF. Included Accessories: User Manual, VPM3 - Virtual Power Meter Software and Manual, 10 ft. USB Cable. Note: The astrisk (*) displayed in the Product Specifications indicates (for temperatures above 35°C or below 15°C add 3.0% to stated accuracies) - this includes the entire "Accuracy-Peak Envelope Power" spec as well.
Contact us for lead time

Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.

More Information
Attribute Value
Manufacturer Bird
Certificates CE EMC EN 61326-1-2006
Impedance Ohm 50.0000
Accuracy - Peak Envelope Power burst width > 200 μs:  ± 7% of reading, + 0.70 W 1 μs < burst width < 200 μs:  ± 10% of reading, + 1.40 W 0.5 μs < burst width < 1 μs:  ± 15% of reading, + 1.40 W burst width < 0.5 μs:  ± 20% of reading, + 1.40 W
Average Power Average Forward Power Range:  500 mW to 500 Watts Avg, 1300 Watts Peak (Derate maximum average power rating from 500W at 300MHz to 100W at 1GHZ using a straight line on a log-log scale) *Accuracy, Average Forward Power:  ± 4% of reading, + 0.17 W Minimum Forward Power for Reflected Measurement:  0.5W Return Loss:  0.0 to 23 dB VSWR:  1.15 to 99.9
Burst Average Power Burst Average Forward Power Range:  13.5 W to 500 Watts Avg Burst Width:  1 μs to 5 ms Repetition Rate:  5 Hz, Min Duty Cycle (D):  .002 to 1.0 *Accuracy, Burst Average Power:  ± 6% of reading, + 0.17 Watts
Complementary cumulative distribution function CCDF Measurement Range:  0.1 to 100% Threshold Measurement Range:  13.5 to 500 W Measurement Uncertainty:  ± 2% *Level Set Accuracy:  As Peak Envelope Power Accuracy + 2.0%
Crest factor Crest Factor Measurement Range:  500 mW to 25 Watts *Accuracy, Crest Factor:  Linear Sum of Peak and Average Power Accuracies
Directivity 29 dB 25 MHz to <50 MHz 30 dB from >50 MHz to 1000 MHz
Frequency Range 25 MHz to 1.0 GHz
Insertion Loss <0.05 dB
Insertion VSWR <1.05
Peak envelope power range 13.5 to 1300 W
Power range 500 mW to 500 Watts Avg. 1300 Watts Peak (Derate maximum average power rating from 500W at 300MHz to 100W at 1GHZ using a straight line on a log-log scale)
Connectors N Female (Both)
Interface DPM Interface: DB9 proprietary interface, PC Interface (1): RS-232, 9600 Baud, no parity, 8 data bits, 1 stop bit, DB9, PC Interface (2): USB 2.0 Type B
Temperature Range Operating: -10 °C to 50 °C (14 °F to 122 °F) Storage: -40 °C to 80 °C (-40 °F to 176 °F)
Dimensions 4.8 in x 4.6 in x 1.3 in (122 mm x 117 mm x 33 mm)
Power Supply USB Port: less than one low-power USB load DC Input Connector: 7-18 VDC at less than 0.1A